96v Mppt Solar Charge Controller
The 96V MPPT Solar Charge Controller is designed for solar charging systems using a 96V battery bank. It regulates PV power according to the battery charging requirements and available solar input, with different charging-current models available for project-specific configurations.
Product Introduction
The 96V MPPT Solar Charge Controller is designed for solar charging systems using a 96V battery bank. It regulates PV power according to the battery charging requirements and available solar input, with different charging-current models available for project-specific configurations.
Key Specifications
|
Parameter |
Specification |
|
Rated System Voltage |
96V DC |
|
Battery Voltage Range |
72–120V DC |
|
Rated Charging Current |
30A / 40A / 50A / 60A / 100A / 120A |
|
MPPT Operating Voltage |
130–180V DC |
|
Maximum PV Voc |
230V DC |
|
Maximum PV Input Power |
Model dependent |
|
MPPT Tracking Efficiency |
≥99% |
|
Conversion Efficiency |
≥98% |
|
Battery Type |
Lead-acid / GEL / LiFePO4 / Li-ion / User-defined* |
|
Charging Method |
MPPT / CC / CV / Float |
|
Lithium Battery Activation |
Supported |
|
Temperature Compensation |
Supported |
|
Communication |
RS485 |
|
Display |
LCD |
|
Protection |
Overvoltage / Overcurrent / Reverse Polarity / Short Circuit / Over-Temperature* |
|
Operating Temperature |
-20°C to +40°C |
|
Altitude |
≤3000m |
|
Protection Rating |
IP21 |
|
Installation |
Fixed / Wall-mounted |
|
OEM Parameter Configuration |
Available |
Match the PV Array Before Selecting the Controller
PV Voc
Keep the array open-circuit voltage below the controller's maximum PV input limit of 230V DC.
PV Vmp
Make sure the array's operating voltage is suitable for the controller's MPPT operating range.
Total PV Power
Match the total PV power to the rated capacity of the selected controller model.
Cold-Weather Voc
Allow for the increase in PV open-circuit voltage at low temperatures when designing the PV string.
PV String Configuration
Confirm the number of panels in series and parallel, along with the resulting Voc, Vmp and total power, before production.
- Also check the battery side: Verify the battery's actual charging voltage against the controller's supported battery voltage range before confirming the model.
Select the Charging Current by Battery Requirement
|
Charging Current |
Main Selection Factor |
|
30A / 40A |
Lower charging demand |
|
50A / 60A |
Medium charging demand |
|
100A / 120A |
Higher charging demand |
The required current should be determined from battery capacity, battery manufacturer's charging limit and the required charging time rather than selecting the largest available current.
Battery Charging Configuration
Lead-acid / GEL: Charging profile, float voltage and temperature compensation can be configured according to the battery requirements.
LiFePO4 / Li-ion: Confirm charge voltage, maximum charging current, activation requirements and BMS compatibility before ordering.
Control, Monitoring & Protection
Local Control
- LCD display: View operating status and configured parameters directly from the controller.
- Charging Current Configuration: Charging current can be configured according to the selected model and battery requirements.
Communication
- RS485 Interface: Supports monitoring and parameter communication on applicable configurations.
Protection
PV overvoltage, battery overvoltage, reverse polarity, overcurrent, short circuit and over-temperature protection.
What to Send for a Quotation
To select the appropriate 96V controller, provide:
- Battery: System voltage / chemistry / capacity
- Battery charging: Required voltage / maximum charging current
- PV: Voc / Vmp / total PV power
- Communication: RS485 or other requirements
- Quantity: Project quantity
- Environment: Installation temperature and location
FAQ
Q: Can the controller be used as a replacement for an existing unit?
A: Yes, if the replacement model matches the existing system requirements and installation conditions. The original wiring and mounting arrangement should be checked before ordering.
Q: Can the existing mounting position be reused?
A: This depends on the selected model's enclosure dimensions and mounting points. Confirm the mechanical drawing before replacing an existing controller.
Q: Does the controller require ventilation around the enclosure?
A: Yes. Leave sufficient clearance around the controller to allow heat to dissipate and avoid installing it close to other heat-generating equipment.
Q: Can parameters be preset before production?
A: Applicable models can be preset according to the agreed project requirements. Parameter settings should be confirmed before production starts.
Q: How should the controller be protected during shipment?
A: The unit should be secured against impact and movement, with suitable protective packaging for its enclosure and electrical connections. Packaging requirements can be confirmed for bulk or export orders.
Q: Are spare units recommended for larger projects?
A: For projects with multiple installations, keeping spare controllers on hand can reduce downtime if a unit requires replacement. The recommended quantity depends on the project scale and operating environment.
Hot Tags: 96v mppt solar charge controller, China 96v mppt solar charge controller manufacturers, suppliers, factory, 60a Mppt 12v 24v 48v Charge Controller, 60v Mppt Solar Charge Controller, 72 Volt Solar Charge Controller, 96v Mppt Solar Charge Controller, mppt charge controller, mppt solar charge controller
You Might Also Like